ACM Extended
ACM EXTENDED / REFERENCE

Cardiac rhythms

Recognition, causes, entry patterns, treatment responses and transition timing for the rhythms implemented in ACM Extended.

Open printable cardiac rhythm chart

Confirm the pulse

Use the ECG together with a pulse check, blood pressure, breathing and perfusion. PEA has an electrical rhythm without a pulse. VT may be perfusing or pulseless. Torsades is pulseless immediately, including its narrower entry pattern.

For the relationship between rhythm, filling, stroke volume, vasoconstriction and systemic vascular resistance, see circulation during hemorrhage and cardiology and oxygen delivery.

01

Choose the treatment path

FindingRhythmsAction
Organized rhythm with a pulse
Sinus, AFib, AFib with RVR, atrial tachycardia, SVT, VT with a pulse
Assess stability and treat the cause. Use SYNC for cardioversion of an appropriate organized tachyarrhythmia.
Shockable arrest
VF, pulseless VT, torsades
CPR and ventilation; defibrillate with SYNC off. Correct reversible causes.
Nonshockable arrest
PEA, asystole
CPR, ventilation and correction of the cause. Do not defibrillate.
Moving or recently shocked trace
CPR/motion artifact or the brief post-shock display
Reassess once the transient clears. An electrical number or a brief flat trace alone does not establish recovery or death.
How to read these monitor examples

Each strip spans six seconds and uses the mod’s ECG shapes, sampling interval and bright green monitor color. The examples hold the electrical rate steady; AFib uses variable intervals. Pulse status must be assessed separately. Motion, compressions and poor electrode contact can change the live display.

The vertical scale shows relative monitor deflection, with upward deflections positive. It is not a calibrated millivolt scale. The torsades strip shows its established appearance; the rhythm’s entry transition is described below.

Sources: native rhythm shapes, custom rhythm shapes, beat timing and monitor color, checked at commit dd50edf.

02

Sinus rhythm

Pulse: Present if perfusion is adequate

Organized P-QRS-T pattern at slower rates. At faster rates the monitor uses a compressed narrow complex pattern.

ECG example75 BPM example
Sinus rhythm monitor waveformSix seconds of the game waveform. Regular P waves, narrow QRS complexes and T waves. Confirm perfusion with a pulse check. Vertical deflections are relative display units, not millivolts.
Regular P waves, narrow QRS complexes and T waves. Confirm perfusion with a pulse check. Hover, tap or enter a time to inspect. Vertical scale is relative, without mV calibration.
ReferenceWhat happens in game
Rate
Follows the patient's actual heart rate
Entry / transient rhythm
Appears directly on recovery or when an induced perfusing rhythm terminates. There is no separate timed entry rhythm.
Common causes
Normal rhythm after stabilization. Pain, blood loss, oxygenation, temperature and medications can move the rate while it remains sinus.
What to do
Assess perfusion, breathing and injury. A normal looking ECG does not prove normal blood volume or adequate ventilation. No shock is indicated for sinus rhythm.
Conversion / deterioration
Changes as physiology changes. If the rate becomes critically high or low, or pressure/oxygenation fails, the native deterioration rules can take over.
03

Sinus bradycardia

Pulse: May be weak; check directly

Organized sinus complexes with longer R-R intervals. This is a rate presentation of sinus rhythm, not a separate selectable electrical rhythm.

ECG example45 BPM example
Sinus bradycardia monitor waveformSix seconds of the game waveform. The same sinus morphology with more time between beats. Check the pulse and pressure. Vertical deflections are relative display units, not millivolts.
The same sinus morphology with more time between beats. Check the pulse and pressure. Hover, tap or enter a time to inspect. Vertical scale is relative, without mV calibration.
ReferenceWhat happens in game
Rate
Slow sinus rate; below 60 BPM is a descriptive band
Entry / transient rhythm
Rate slows progressively according to the cause. There is no fixed countdown or separate entry waveform.
Common causes
Hypoxia, hypothermia, drug depression/toxicity and late circulatory failure. A head injury with a Cushing response can also slow the rate.
What to do
Correct oxygenation/ventilation and assess pressure, temperature and medication exposure. Atropine can raise rate; identify whether the underlying cause needs reversal, rewarming or another intervention.
Conversion / deterioration
Below 40 BPM outside an existing critical vitals grace period, the game enters its fatal rate pathway. VF is the usual electrical selection; active adenosine can instead select asystole. This is game behavior, not a requirement to wait for that threshold.
04

Sinus tachycardia

Pulse: Present until perfusion fails

Regular narrow complexes, with less room between beats. P and T detail compresses at high rates.

ECG example130 BPM example
Sinus tachycardia monitor waveformSix seconds of the game waveform. The game compresses the sinus complex at this rate. The underlying cause still determines perfusion. Vertical deflections are relative display units, not millivolts.
The game compresses the sinus complex at this rate. The underlying cause still determines perfusion. Hover, tap or enter a time to inspect. Vertical scale is relative, without mV calibration.
ReferenceWhat happens in game
Rate
Fast sinus rate; above 100 BPM is a descriptive band
Entry / transient rhythm
Tracks the patient's changing rate. Hemorrhagic tachycardia does not automatically become SVT under the default settings.
Common causes
Blood loss, pain, hypoxia, physiological stress, epinephrine or distress during inadequate sedation/paralysis.
What to do
Control hemorrhage, replace volume, treat pain, support ventilation and reassess any pressor or sedative delivery. Adenosine does not treat the underlying sinus response.
Conversion / deterioration
A sustained pressor surge can induce atrial tachycardia or SVT. A native rate above 220 BPM can enter VT with a pulse and then the critical vitals pathway.
05

Atrial fibrillation

Pulse: Usually present

Irregularly irregular narrow complexes with a fibrillatory baseline and no consistent P wave.

ECG example90 BPM nominal example
Atrial fibrillation monitor waveformSix seconds of the game waveform. Uneven beat spacing and a fibrillatory baseline. The rate is a nominal example; individual intervals vary. Vertical deflections are relative display units, not millivolts.
Uneven beat spacing and a fibrillatory baseline. The rate is a nominal example; individual intervals vary. Hover, tap or enter a time to inspect. Vertical scale is relative, without mV calibration.
ReferenceWhat happens in game
Rate
Controlled target about 90 BPM
Entry / transient rhythm
Can be induced directly or follow rate control of AFib with RVR. The rhythm label changes immediately when treatment is effective; the actual heart rate can settle progressively. No separate timed entry stage is drawn.
Common causes
Rate controlled AFib with RVR, or an instructor created scenario. Severe hypothermia can initiate the faster RVR presentation.
What to do
Follow pulse, pressure and symptoms. Correct cold exposure and other physiological problems. Synchronized cardioversion can convert this modeled rhythm to sinus when intervention is appropriate.
Conversion / deterioration
Rate control does not itself restore sinus rhythm. Successful synchronized cardioversion restores sinus; native critical deterioration overrides the perfusing rhythm.
06

Atrial fibrillation with RVR

Pulse: Present, with impaired perfusion possible

Fast, irregularly irregular narrow complex rhythm. Uneven R-R intervals and a fibrillatory baseline distinguish it from regular SVT.

ECG example150 BPM nominal example
Atrial fibrillation with RVR monitor waveformSix seconds of the game waveform. Fast, uneven beat spacing with a fibrillatory baseline. Assess whether the patient remains perfusing. Vertical deflections are relative display units, not millivolts.
Fast, uneven beat spacing with a fibrillatory baseline. Assess whether the patient remains perfusing. Hover, tap or enter a time to inspect. Vertical scale is relative, without mV calibration.
ReferenceWhat happens in game
Rate
Default target about 150 BPM
Entry / transient rhythm
Starts directly when induced. At core temperature 32°C or lower there is a 15% chance on each eligible cooling check; this is probabilistic, so there is no fixed onset time.
Common causes
Severe hypothermia and instructor induction. The modeled rhythm adds a 28 mmHg pressure penalty and can produce discomfort and brief obtundation.
What to do
Rewarm and assess perfusion. Esmolol or amiodarone can rate control it to AFib. Synchronized cardioversion can restore sinus. Adenosine does not terminate AFib.
Conversion / deterioration
Rate control targets AFib near 90 BPM after enough medication effect develops. Successful cardioversion restores sinus immediately, followed by the short post-shock display period. Ongoing native deterioration can still produce arrest.
07

Atrial tachycardia

Pulse: Present

Regular fast narrow complexes. The small atrial deflection is easiest to see when the rate leaves enough space between complexes.

ECG example185 BPM example
Atrial tachycardia monitor waveformSix seconds of the game waveform. Regular narrow complexes with a small atrial deflection before the main spike. Vertical deflections are relative display units, not millivolts.
Regular narrow complexes with a small atrial deflection before the main spike. Hover, tap or enter a time to inspect. Vertical scale is relative, without mV calibration.
ReferenceWhat happens in game
Rate
Default target about 185 BPM
Entry / transient rhythm
Can be induced directly, or after about 6 seconds of a sustained qualifying pressor surge. The rhythm appears directly once induced; no additional timed entry pattern follows.
Common causes
Excess epinephrine related drive or stacked measured push dose support, with the patient already tachycardic. It adds a 12 mmHg pressure penalty and discomfort.
What to do
Check medication concentration and actual infusion rate. Esmolol or amiodarone can terminate it; synchronized cardioversion is available. Adenosine's dedicated conversion effect is limited to SVT.
Conversion / deterioration
Successful medication conversion or cardioversion returns to sinus. Reducing the original surge is still necessary, because conversion alone does not remove the cause.
08

Supraventricular tachycardia (SVT)

Pulse: Present, may be poorly perfusing

Regular rapid narrow complexes, generally without a clearly separated P wave. It should not look like the broad complexes of VT.

ECG example190 BPM example
Supraventricular tachycardia (SVT) monitor waveformSix seconds of the game waveform. Regular, rapid narrow complexes. The trace does not determine whether pressure is adequate. Vertical deflections are relative display units, not millivolts.
Regular, rapid narrow complexes. The trace does not determine whether pressure is adequate. Hover, tap or enter a time to inspect. Vertical scale is relative, without mV calibration.
ReferenceWhat happens in game
Rate
Default target about 190 BPM
Entry / transient rhythm
Direct induction, or about 6 seconds of a stronger qualifying pressor surge. There is no separate timed narrow to wide entry sequence. The old optional rate only trigger is disabled by default and is not an exposed Addon Option.
Common causes
A sufficiently strong epinephrine/push dose surge or instructor induction. The rhythm adds an 18 mmHg pressure penalty and can cause discomfort or obtundation.
What to do
Rapid IV / IO adenosine can terminate the modeled regular SVT. Complete the required flush when enabled. Esmolol and amiodarone are additional modeled conversion paths; synchronized cardioversion can restore sinus.
Conversion / deterioration
A qualifying adenosine dose attempts conversion after about 1 second of systemic effect. It briefly slows rate without deliberately creating asystole. Other drug conversions depend on active effect rather than a fixed bag hanging timer.
09

Ventricular tachycardia with a pulse

Pulse: Present; verify before choosing shock mode

Regular broad ventricular complexes with little normal P-QRS-T separation.

ECG example230 BPM example
Ventricular tachycardia with a pulse monitor waveformSix seconds of the game waveform. Broad ventricular complexes. This example has a pulse; pulse assessment determines the treatment path. Vertical deflections are relative display units, not millivolts.
Broad ventricular complexes. This example has a pulse; pulse assessment determines the treatment path. Hover, tap or enter a time to inspect. Vertical scale is relative, without mV calibration.
ReferenceWhat happens in game
Rate
Uses the patient's actual heart rate
Entry / transient rhythm
The native fatal rate pathway selects VT when heart rate exceeds 220 BPM outside a critical grace period. No separate timed entry morphology is implemented for this rhythm.
Common causes
Extreme physiological or drug related tachycardia. The underlying circulatory condition determines whether the patient remains perfusing.
What to do
Use synchronized cardioversion for an unstable perfusing VT. IV / IO lidocaine has a conversion path in the current mod. Correct the cause of the extreme rate. The AED's automatic analysis does not advise defibrillation for this perfusing VT.
Conversion / deterioration
Critical deterioration can lead to pulseless VT or another arrest rhythm. The native recovery check can clear VT when heart rate is above 45 and below 200 BPM and MAP is above 60 and below 180 mmHg. There is no extra fixed six second recovery hold in the current observer.
10

Pulseless ventricular tachycardia

Pulse: Absent

Broad, rapid ventricular complexes. The waveform alone does not establish whether a pulse exists.

ECG example230 BPM electrical example
Pulseless ventricular tachycardia monitor waveformSix seconds of the game waveform. The same broad waveform can occur without a pulse. This example is cardiac arrest. Vertical deflections are relative display units, not millivolts.
The same broad waveform can occur without a pulse. This example is cardiac arrest. Hover, tap or enter a time to inspect. Vertical scale is relative, without mV calibration.
ReferenceWhat happens in game
Rate
Displayed electrical rate generally 200–240 BPM
Entry / transient rhythm
Selected at arrest or after deterioration from a critical fast rhythm. There is no separate timed entry waveform.
Common causes
Deterioration of severe tachycardia, critical injury or an induced arrest scenario.
What to do
CPR, effective ventilation, defibrillation with SYNC off, and correction of reversible causes. Amiodarone and IV / IO lidocaine can improve defibrillation response.
Conversion / deterioration
Without effective CPR, it can deteriorate to VF and then asystole through randomized checks. Successful defibrillation still requires the patient's ROSC conditions to be met. Repeating a native VF/pulseless VT shock within 60 seconds of the previous recorded shock can instead cause asystole in the current game.
11

Ventricular fibrillation

Pulse: Absent

Continuous chaotic deflections without organized QRS complexes. The electrical display can vary roughly 100–220 BPM, but this is not a pulse.

ECG exampleNo organized rate
Ventricular fibrillation monitor waveformSix seconds of the game waveform. Chaotic activity without consistent QRS complexes. A displayed electrical number would not be a pulse. Vertical deflections are relative display units, not millivolts.
Chaotic activity without consistent QRS complexes. A displayed electrical number would not be a pulse. Hover, tap or enter a time to inspect. Vertical scale is relative, without mV calibration.
ReferenceWhat happens in game
Rate
No organized ventricular rate; the monitor may show an electrical number
Entry / transient rhythm
Appears directly at arrest or after deterioration from pulseless VT. No separate timed coarse to fine entry sequence is implemented.
Common causes
Critical injury, severe physiological deterioration, progression of another arrest rhythm, or an unsynchronized shock to an organized perfusing rhythm.
What to do
CPR, ventilation and defibrillation with SYNC off. Check blood volume, oxygenation and chest causes. Amiodarone/lidocaine can improve the modeled shock response.
Conversion / deterioration
Can deteriorate to asystole when CPR is absent and randomized deterioration checks succeed. A successful shock does not guarantee ROSC if circulation remains inadequate.
12

Torsades de pointes

Pulse: Absent from the moment it is induced

Polymorphic ventricular complexes with changing amplitude and polarity, forming the characteristic twisting pattern.

ECG example220 BPM electrical example
Torsades de pointes monitor waveformSix seconds of the game waveform. Established torsades after its entry transition: complexes change shape, amplitude and polarity. The patient is pulseless throughout the entry stage too. Vertical deflections are relative display units, not millivolts.
Established torsades after its entry transition: complexes change shape, amplitude and polarity. The patient is pulseless throughout the entry stage too. Hover, tap or enter a time to inspect. Vertical scale is relative, without mV calibration.
ReferenceWhat happens in game
Rate
Default electrical target about 220 BPM
Entry / transient rhythm
Starts with a narrower, SVT like rapid pattern. Every fourth beat becomes more ventricular early, then the whole run gradually widens and develops its twisting amplitude. The default entry transition lasts 15.84 seconds, equivalent to three 5.28-second monitor sweeps.
Common causes
Marked hypocalcemia, raised ICP or cumulative amiodarone exposure of at least 2.2 g. The trigger is probabilistic, including the severe tier; it is not guaranteed to fire immediately. It can also be induced for training.
What to do
Treat as pulseless arrest throughout the entry transition: CPR, effective ventilation and defibrillation with SYNC off. Magnesium can terminate it once sufficient active effect develops. Correct low calcium or raised ICP and stop excessive amiodarone exposure.
Conversion / deterioration
Magnesium suppresses recurrence while enough active effect remains. After magnesium assisted conversion there is a short default 20-second recurrence protection period; defibrillation uses a separate short protection period. The underlying cause can re-induce torsades after protection/effect fades. Amiodarone does not treat this modeled rhythm.
13

Pulseless electrical activity (PEA)

Pulse: Absent despite organized ECG activity

Organized abnormal complexes with beat to beat variation. The monitor's BPM is an electrical rate and does not establish mechanical circulation.

ECG example80 BPM electrical example
Pulseless electrical activity (PEA) monitor waveformSix seconds of the game waveform. Organized abnormal complexes with no mechanical pulse. PEA can have several appearances; the monitor alone cannot diagnose perfusion. Vertical deflections are relative display units, not millivolts.
Organized abnormal complexes with no mechanical pulse. PEA can have several appearances; the monitor alone cannot diagnose perfusion. Hover, tap or enter a time to inspect. Vertical scale is relative, without mV calibration.
ReferenceWhat happens in game
Rate
Electrical display varies within 60–100 BPM
Entry / transient rhythm
Appears directly when reversible circulatory failure selects PEA. There is no separate fixed bradycardic entry rhythm in the current build.
Common causes
Severe blood loss, severe hypoxia, tension pneumothorax or a large hemothorax. The ECG alone does not identify which cause is present.
What to do
CPR, effective ventilation and rapid correction of the cause. Control bleeding and restore circulating volume; treat obstructive chest injury. Do not defibrillate PEA.
Conversion / deterioration
Eligibility is rechecked every 5 seconds. Corrected PEA can attempt ROSC without waiting for a shock. After 6 minutes, the reversible PEA handling expires and the general arrest selection resumes; this does not guarantee a particular next rhythm.
14

Asystole

Pulse: Absent

Near flat baseline with small monitor noise; no organized ventricular complexes.

ECG example0 BPM
Asystole monitor waveformSix seconds of the game waveform. Low baseline noise without organized complexes. Reassess the patient and monitor connection. Vertical deflections are relative display units, not millivolts.
Low baseline noise without organized complexes. Reassess the patient and monitor connection. Hover, tap or enter a time to inspect. Vertical scale is relative, without mV calibration.
ReferenceWhat happens in game
Rate
0 BPM
Entry / transient rhythm
Can appear directly with profound blood loss or another severe arrest cause, or after VF deterioration. No separate timed entry waveform is implemented.
Common causes
Profound blood loss, progressive untreated arrest, severe lidocaine toxicity or an inappropriate/refractory shock. Blood volume below 3.1 L can select asystole in the arrest handler.
What to do
CPR, effective ventilation and correction of reversible causes. Defibrillation is not indicated. Use actual pulse and circulation findings to assess recovery.
Conversion / deterioration
A flatline alone does not determine whether the unit is dead. Recovery requires a living patient and successful resuscitation with adequate circulation; dead units cannot regain medication effects or ROSC.
15

Transition timing

TransitionDefault timingHow to interpret it
Pressor surge > atrial tachycardia or SVT
About 6 s after a sustained qualifying surge
The patient must already be tachycardic and perfusing. A stronger surge selects SVT. A 90-second refractory period limits repeated automatic induction.
Cold patient > AFib with RVR
Random eligible cooling checks at ≤32°C
15% per eligible cooling check. No fixed delay can be promised.
Torsades entry > developed twisting pattern
15.84 s
A visual transition across three monitor sweeps. Arrest begins immediately, so do not wait for the broad twisting pattern before treating.
Adenosine > SVT conversion attempt
About 1 s after effective rapid delivery
For a 6 mg reference push delivered over 5 s, conversion strength is sufficient in this model. Required line flush and actual delivery determine when the clock starts.
Esmolol > rate control/conversion
Dose- and delivery dependent
A full reference IV dose reaches the current rate control threshold at roughly 4.6 s; its reference peak is 20 s. An infusion reaches that effect later.
Amiodarone > atrial rhythm response
Dose- and delivery dependent
A full reference IV dose reaches the AFib-RVR/atrial tach response threshold at roughly 2.6 s and the SVT threshold at roughly 5 s. These are modeled effect thresholds, not a delay from connecting a bag.
Magnesium > torsades termination/suppression
Dose- and delivery dependent
For a fully delivered 2 g reference: about 21 s to termination effect, about 15 s to suppression effect, 90 s to peak. Conversion still requires ROSC eligibility.
Critical vitals > worsening instability
Initial grace 15–30 s; persistent severe values can cause arrest after roughly 30–45 s
Checks run every 1 s. Very extreme rate/pressure or a nonperfusing rhythm can end the grace sooner.
Pulseless VT > VF > asystole without CPR
Random checks every 15–30 s
A check must also pass a randomized 30–60 s minimum since deterioration gate and the deterioration chance. This is not a fixed per rhythm countdown.
Reversible PEA > ROSC check
Every 5 s, up to a 6 min handling window
Correction can produce an earlier attempt. Expiry returns to general arrest selection, rather than guaranteeing asystole.
Shock > live monitor/pulse display
About 2 s
The short post-shock display is shared by defibrillation/cardioversion. It is separate from the 60 s native repeat shock consequence.

Conversion changes the rhythm state when the treatment succeeds. The monitor then displays the new pattern as it redraws. Heart rate can settle over time, so electrical conversion and normalization of rate or pressure are not the same event.

16

Critical vitals progression

Finding during the critical periodCurrent behavior
Heart rate >245 or <10 BPM, or MAP >220 or <30 mmHg
Can trigger arrest on the next 1-second critical vitals check.
Heart rate >240 or <30 BPM, or MAP >200 or <55 mmHg
If still present beyond the initial 15–30 s grace plus 15 s, the critical handler can trigger arrest.
Heart rate >45 and <200 BPM, MAP >60 and <180 mmHg, no arrest
The critical handler can resolve; perfusing VT can return to sinus.
Severe hypoxia or class IV hemorrhage
Separate native pathways can cause arrest without waiting for the rate/pressure grace.
No effective circulation when the patient deteriorates
PEA is selected. With circulation present, a rate above 200 BPM favors a pulseless VT target; lower rates favor VF. General arrest selection can still choose between VF and pulseless VT.

These boundaries explain the game’s transitions. They are not treatment targets to wait for. A patient can already be unstable well before crossing an arrest threshold.

17

Monitor transients and artifacts

Trace or transientWhat you seeDuration / response
Torsades entry
Narrower rapid complexes with increasing ventricular ectopy, then broader twisting complexes
15.84 s by default; pulseless throughout.
After a shock
Brief near flat trace and unavailable pulse/electrical rate reading
About 2 s, then the live rhythm. Successful ROSC may clear the recent shock state sooner.
Adenosine
Brief slowing; conversion to sinus only if the SVT treatment conditions are met
Effect builds for about 1 s, holds briefly and decays within 15 s. No deliberately programmed standstill strip.
CPR
Compression related deflections and movement artifact
Present while CPR is active. Compression activity does not prove spontaneous circulation.
Direct pressure, suction, bagging or hands on treatment
Baseline disturbance layered over the rhythm
Follows movement/procedure activity. Recent bagging contributes for about 1.2 s.
PEA rate drift
Organized complexes with a slowly varying displayed rate inside 60–100 BPM
The electrical rate is refreshed about once a second; it is not a hidden palpable pulse.
Ordinary rhythm switch
The new waveform enters the advancing sweep
No named intermediate rhythm or fixed multi second morph is implemented for sinus, AFib, atrial tachycardia, SVT, VT, pulseless VT, VF, PEA or asystole.
18

Cardioversion and defibrillation

RhythmModeModeled response
AFib / AFib with RVR
SYNC on
90% conversion chance per synchronized shock.
Atrial tachycardia / SVT
SYNC on
97% conversion chance per synchronized shock.
VT with a pulse
SYNC on
90% fallback conversion chance. Check that the rhythm is perfusing.
Torsades
SYNC off
95% chance to attempt conversion, followed by the shared ROSC check.
VF / pulseless VT
SYNC off
Response depends on resistance, current amiodarone/lidocaine effect and CPR history. Current full lidocaine effect can make a conversion attempt certain; ROSC still requires adequate circulation.
Organized perfusing rhythm shocked with SYNC off
Wrong mode
55% default chance of inducing VF. A lack of immediate VF does not make this the correct mode.
VF / pulseless VT / torsades with SYNC on
Wrong mode
The shock is blocked because there is no suitable R wave for synchronization.
Sinus, PEA or asystole shocked
No indicated shock
The current manual shock path can place the patient into asystolic arrest.

The short 2-second post-shock display period does not remove the separate native repeat shock rule. For VF/pulseless VT, a shock within 60 seconds of the previous recorded shock can select asystole. The current transaction records synchronized shocks too, so check recent treatment history before another shock.

19

ROSC and reversible causes

RequirementWhat to assess or correct
Living patient with circulating volume strictly above 4.2 L
Control hemorrhage and restore volume. A shock cannot compensate for an empty circulation.
SpO2 at least 67% in the native circulation check
Open/clear the airway and provide effective ventilation and oxygen. Adequate numbers require actual delivered breaths.
No active tension pneumothorax
Assess the chest and decompress the obstructive injury.
Hemothorax not above 1.2 L in the native check
Treat the chest injury and blood loss.
[HARDCORE] Cardiac Rhythms enabled
Also requires temperature at least 30°C, modeled arterial CO2 below 85 mmHg, and resolution of the lidocaine toxicity arrest restriction.

Find [HARDCORE] Cardiac Rhythms under Addon Options > ACM Extended: Systems > Hardcore. It changes the extra ROSC requirements; it does not increase torsades frequency or shorten its entry pattern. An attached ventilator does not prevent starting CPR in the current mod.

20

Addon options and scenario testing

LocationAvailable optionWhat it changes
ACM: Circulation > Cardiac Arrest
Rhythm Deterioration Multiplier
Changes the chance of deterioration during arrest. Default 1.0 gives a 40% roll when the other no CPR/time requirements pass. Range 0–2.
ACM: Circulation > Cardiac Arrest
Critical Damage Cardiac Arrest Chance
Chance of arrest from critical damage. It does not change every physiological arrest threshold.
ACM: Circulation > CPR
CPR Effectiveness Multiplier
Changes overall CPR effectiveness. Default 1.0.
ACM Extended: Systems > Hardcore
[HARDCORE] Cardiac Rhythms
Adds the extra reversible cause ROSC restrictions listed above.
ACM Extended: Circulation > Medications
Require saline flush after push
Changes when selected IV / IO pushes reach the patient and begin taking effect.
ACM Extended: Systems > Blood
Cold blood causes hypothermia
Unwarmed blood can lower temperature and contribute to the conditions that trigger AFib with RVR.
ACM Extended: Debug > Overlay
Debug menu
Opens the diagnostic display used to compare rhythm, medication delivery and patient state during a test.

Rhythm entry durations, per rhythm cardioversion percentages and automatic surge thresholds are current build defaults. They do not have corresponding end user sliders in this build. Use the exposed options above for mission tuning.

For a repeatable test, use the same patient, medication concentration, delivery rate and addon settings. Record the pulse, blood pressure, displayed rhythm, time of systemic medication delivery, and time of conversion. For torsades, record arrest onset separately from the end of its 15.84-second entry pattern.

Sources and revision