Oxygen delivery

Why a casualty can have normal SpO₂ and still receive too little oxygen at the tissues. Hemorrhage affects filling and flow; dilution affects oxygen carrying content; altitude and lung disease affect saturation.

Read oxygenation and perfusion

02

SpO₂ during hypovolemia and poor perfusion

A normal saturation can coexist with severe shock. SpO₂ describes the oxygen saturation of the hemoglobin being sampled. It does not tell you how much blood remains, how much hemoglobin is circulating, or how much oxygen reaches the tissues each minute.

Saturation

How full are the available oxygen binding sites? The remaining blood can stay well saturated when the airway and lungs still work.

Oxygen content

How much oxygen can that blood carry? Less hemoglobin means less oxygen content at the same saturation. Losing red cells and plasma together can initially preserve concentration while total circulating volume falls.

Oxygen delivery

How much reaches tissue per minute? Hemorrhage reduces filling and flow. A high saturation does not replace that lost flow.

Sources and revision

Physiology background: OpenStax, oxygen transport and hemoglobin saturation. The model examples below show the separate effect of blood volume and flow.

Why the probe becomes less reliable

Check the signal quality

Pulse oximetry also needs a usable pulsatile signal at the probe. Poor circulation and cold skin can reduce reading reliability. During hypovolemia, peripheral vasoconstriction and reduced perfusion can therefore make the signal weak or unavailable. A displayed number may be misleading; there is no dependable rule that every poor perfusion error points downward.

ObservationWhat it can meanRead alongside it
Normal SpO₂ with weak pulses
Saturation may be adequate while blood flow and tissue delivery are inadequate
Bleeding, pulse quality, pressure, mental state and circulation trend
Erratic value or poor pulse signal
The probe may not have a reliable arterial signal
Probe placement, local perfusion and whether its pulse rate matches an assessed pulse
Low SpO₂
May reflect true impaired oxygenation, measurement error, or both
Airway, respiratory effort, chest findings, waveform quality and repeat measurements
No useful reading
Does not establish an arterial saturation of zero
Patient assessment and other monitoring; do not wait for a reassuring number

Other real world limitations include skin pigmentation, skin temperature and nail polish. These are background device limitations; the game specific effects are listed separately below. FDA pulse oximeter limitations.

SpO₂ also does not measure ventilation or CO₂ clearance. Compare it with breathing, delivered ventilator volumes and the capnography waveform explorer.

03

What the pulse oximeter actually simulates

In gameUnderlying value and displayed reading

The mod has an underlying oxygen value and a separate pulse oximeter reading. The displayed reading adds measurement variation and blood volume/pressure effects. The DO₂ calculation reads the underlying oxygen value, so copying a distorted monitor number into the calculator will not reproduce the patient’s hidden DO₂ exactly.

Systolic pressureAt least 80 mmHgBelow this, the reviewed device paths lose their reading
Peripheral pulseRequiredElectrical activity alone does not satisfy this check
Probe limbNo tourniquetA tourniquet on that limb blocks the reading
Implemented effectCurrent behaviorPractical implication
Blood volume distortion
Subtracts a term rising from 0 to 25 points as the native blood volume readout falls from 5.5 to 3 L. That term is scaled by underlying oxygen ÷ target oxygen
The displayed SpO₂ can fall even when underlying oxygen is unchanged. This is a game measurement rule
Low pressure term
Adds 0 to 15 points as systolic pressure falls from 90 to 80 mmHg, before the no reading cutoff below 80
The arithmetic can partly offset the blood loss subtraction. A rising display does not necessarily show improving oxygenation
Measurement variation
Random spread increases as underlying oxygen falls; the nominal spread is 1 point at 95% and 5 points at 75%
Read trends and reassess the patient. The displayed sample need not match the underlying value
Very slow rate
The fingertip device suppresses its reading below 30 BPM. The shared SpO₂ function returns no reading below 20 BPM
The fingertip and AED paths have slightly different low rate gates
Update timing
Pulse oximeter readings refresh approximately every 3–4 seconds in the reviewed paths
Allow for update delay after an intervention; it is not a breath by breath saturation measurement
Same oxygen, different displayed numberGame calculation example

Hold native blood volume at 4 L, underlying oxygen at 97%, and target oxygen at 97%. Assume a detected peripheral pulse, no tourniquet and a sufficient heart rate. Removing random variation isolates the current measurement formula:

SBP 100 mmHg
82%97 − 15 + 0
SBP 85 mmHg
89.5%97 − 15 + 7.5, rounds to 90%
SBP 79 mmHg
No readingSignal gate fails
Underlying oxygen
97%Held constant in all three cases

This illustrates the game’s display arithmetic. It is not a correction formula for a real pulse oximeter or a prediction that human saturation rises when pressure falls.

The reviewed pulse oximeter code does not separately model optical errors from skin pigmentation, nail polish or probe motion. Cold can affect the casualty through other systems, but the shared reading formula has no direct skin temperature input.

Sources and revision

Checked against ACM Extended 21f8694: reading calculation · fingertip device · AED monitoring · underlying oxygen used by DO₂.

Understand oxygen delivery

01

Content × flow

DO₂Oxygen delivery=Cardiac outputBlood flow×Arterial oxygen contentOxygen carried in the blood

Physiology: cardiac output is HR × stroke volume. Arterial oxygen content depends mainly on hemoglobin concentration and the fraction saturated with oxygen, plus a small dissolved component. SpO₂ estimates saturation; it does not measure circulating hemoglobin mass or blood flow.

In gameWhat the DO₂ percentage represents

In ACM Extended: delivery is a fraction of a healthy reference. It combines a blood content estimate, SpO₂ and a flow estimate based on volume and heart rate. A value of 100% means the default model reference, not a clinical oxygen delivery measurement in mL/min.

For the class definitions and the circulation terms, see hemorrhage classes and stroke volume and SVR.

04

Hemorrhage and resuscitation examples

Every row below lists its assumptions. These are snapshots calculated from the current model, not fixed outcomes of a hemorrhage class. Infused amounts represent fluid already admitted to the corresponding circulating compartment.

ScenarioBloodSalineHRSpO₂PPV / PEEPSV estimateDO₂
Baseline
6.0 L
0.0 L
75 /min
97%
Off
100.0%
100.0%
20% loss
4.8 L
0.0 L
110 /min
97%
Off
70.0%
83.0%
35% loss
3.9 L
0.0 L
130 /min
97%
Off
50.2%
64.9%
45% loss
3.3 L
0.0 L
140 /min
97%
Off
38.4%
51.7%
35% loss + PPV
3.9 L
0.0 L
130 /min
97%
5 cmH₂O
44.4%
57.5%
35% loss + PPV, higher PEEP
3.9 L
0.0 L
130 /min
97%
15 cmH₂O
41.5%
53.7%
35% loss + 1 L saline
3.9 L
1.0 L
130 /min
97%
Off
72.3%
74.4%
35% loss + 1 L blood
4.9 L
0.0 L
130 /min
97%
Off
72.3%
93.5%
35% loss + lower saturation
3.9 L
0.0 L
130 /min
85%
Off
50.2%
56.9%

Compare the replacement examples

At 35% blood loss, the example rate of 130 supports DO₂ to about 65% while estimated SV is about 50%. A higher rate does not restore filling. Adding one liter of saline improves the example to about 74%; adding one liter of blood improves it to about 94%. The saline example includes its immediate dilution effect. All examples hold other inputs constant.

The lower saturation row represents the same hemorrhaged casualty with an additional oxygenation problem. It is not tied to a particular altitude. See Flight Physiology for the altitude model.

05

Explore the game calculation

Stroke volume estimate50.2%Flow estimate64.9%Relative hemoglobin concentration100%Oxygen delivery64.9%

Uses default game constants and fresh saline dilution. Values are relative to the model reference. PEEP affects this calculation only with an active ventilator; BVM uses the game’s PEEP-5 reference. Use this for perfusing scenarios; an ECG rate during arrest does not establish mechanical output.

Calculation and limits

Circulating volume is blood + saline + plasma. The preload ratio is circulating volume ÷ 6 L, capped at 1.1. Estimated SV is that ratio raised to 1.6, with the positive pressure penalty applied when relevant.

The rate multiplier starts at 1 + 0.4 × (HR ÷ 75 − 1), limited to 0.3 through 1.35. Above 150 BPM, an additional filling penalty increases toward 220 BPM and scales with the volume deficit. These are game approximations, not a universal human Frank–Starling curve.

Relative hemoglobin concentration is blood ÷ (blood + effective saline dilution + plasma), capped at 1. Delivery is this fraction × SV estimate × rate multiplier × (SpO₂ ÷ 97). The calculator uses freshly added saline, so effective dilution equals the saline input.

In the running game, saline’s modeled dilution contribution has a 20-minute half-life and follows changes in the saline compartment. That decay does not itself remove the saline volume. It is separate from fluid volume conversion. Plasma does not use this saline dilution decay.

The native blood pressure calculation has a separate cardiac output approximation. This calculator reproduces the DO₂ estimate and cannot predict exact cuff readings, rhythm transitions, drug responses or arrest.

What changes delivery

06

Positive pressure and preload

Raising pressure inside the chest opposes venous return. A casualty with reduced circulating volume has less reserve to tolerate that change. PEEP keeps pressure elevated between breaths and can increase the filling cost.

Positive pressure adds a filling penaltyAt constant heart rate 130 and saturation 97, oxygen delivery declines with blood loss. Active positive pressure at PEEP 5 reduces delivery further, and PEEP 15 has a larger penalty.Oxygen delivery relative to healthy reference0%50%100%150%01020304050Blood loss from the 6 L game baseline (%)No PPVPPV, PEEP 5PPV, PEEP 15
Positive pressure adds a filling penalty. Exact default model with HR held at 130 BPM, SpO₂ 97%, no non-red-cell fluid and PEEP in cmH₂O. Active BVM uses the PEEP-5 reference in this calculation; an active ventilator uses its effective PEEP. These curves describe the filling cost alone. Ventilation may also improve saturation.

For the 35%-loss example, PPV at PEEP 5 reduces the remaining SV estimate by about 11.5%; PEEP 15 reduces it by about 17.2%. The reduction multiplies what is left of SV, rather than subtracting those points from a normal SV of 100%.

Correct hemorrhage and inadequate oxygenation together. The model includes the consequences of delayed oxygenation as well as the filling cost of ventilation. Reassess pulse, pressure, chest findings and oxygenation after starting support or changing PEEP.

07

Cardiology factors

FactorPhysiological relationshipHow to interpret it in the game
Sinus tachycardia
Can partially compensate for low SV. Extreme rates shorten diastole and filling time.
Treat the cause of a compensatory rate. Slowing a hemorrhaging casualty’s sinus rate does not replenish volume.
AFib, AFib-RVR and SVT
Irregular or rapid rhythms can reduce effective filling. Loss of coordinated atrial contraction can matter in susceptible hearts.
The rhythm system applies its own rate and pressure effects. The DO₂ approximation uses volume and rate; it does not contain a separate atrial kick variable. See the rhythm cards for actual treatments.
Ventricular rhythms and PEA
Electrical activity alone cannot establish useful mechanical output.
Assess a pulse and arrest state. True PEA has no mechanical output in the native cardiac output path. Do not use a displayed electrical rate as proof of circulation.
Coronary perfusion
Left ventricular coronary supply occurs largely during diastole. Low diastolic pressure and short diastole reduce supply while tachycardia increases demand.
Coronary flow and oxygen demand are physiological background here. The reviewed DO₂ and native output calculations have no coronary flow or coronary pressure input; rapid rate and shock follow their separately implemented rules.
Acidosis and calcium
Poor tissue delivery promotes metabolic debt; acidosis and hypocalcemia can impair myocardial function.
Calcium deficit reduces vascular tone and pressor responsiveness. Acidosis blunts pressure support. These are indirect approximations; the DO₂ formula has no separate contractility factor. Blood pressure can remain abnormal after volume begins to recover.
Vasoconstriction and pressors
Increased resistance can maintain MAP despite reduced flow.
A higher cuff pressure alone does not establish restored DO₂. Reassess volume, oxygenation and perfusion together.
Sources and revision

Implementation checked on 13 September 2026: DO₂ and preload, native output, resistance composition, blood pressure, and circulation and calcium effects.

Circulatory terms and implementation distinguishes modeled effects from background physiology. Cardiac rhythms lists the available presentations, transitions and game specific treatment responses. OpenStax cardiac physiology provides the physiological background.

08

Tissue delivery and brain injury

A stable mild or moderate TBI can now lose its acute burden while structural injury remains in the history. Recovery still requires adequate oxygen delivery. Hemorrhage can keep the acute injury active even with a normal saturation and an acceptable cuff pressure.

Delivery deficit

Below 70% of the healthy game reference, TBI records a delivery deficit. Once present, the deficit clears at 78% or higher. Lower delivery increases secondary injury, reaching the severe weighting at 35%.

Pressure and ICP

The model’s effective MAP must meet the structural injury’s recovery requirement and ICP must be at or below 25 mmHg. Severe structural TBI also needs CPP at least 55 mmHg; critical injury needs 60 mmHg. Mild and moderate injury have no added high CPP floor.

Breathing and recovery

The default recovery check also requires underlying SpO₂ at least 90% and the TBI ventilation ratio at least 0.9. A cleared delivery deficit, adequate perfusion and adequate breathing must occur together.

Reperfusion and renewed deficit

After delivery recovers, a 45-second TBI reperfusion window suppresses renewed injury accrual from low delivery. A new deficit still prevents the recovery check from passing until it clears. The separate general delivery model uses a critical reference below 50% and a clearing reference of 58%.

In gameEffective brain MAP

Head elevation subtracts 6 mmHg from the MAP used by the TBI model, so its effective MAP can be lower than the cuff value. These are game model defaults, not monitor targets or a guaranteed recovery timer. See the severity table and recovery guide for the MAP requirement, retained injury floors and the distinction between cerebral autoregulation and systemic autonomic tone.